<![CDATA[Kung Shin Plastics Co., Ltd.]]> http://www.saykia-corp.com Thu, 1 Jan 1970 08:00:00 +0800 3600 <![CDATA[HME Heat & Moisture Exchanger (SK200)(2011/May/26 18:38:34)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK200.html?CID=1_1 Thu, 26 May 2011 18:38:34 +0800 <![CDATA[HME Heat & Moisture Exchanger (SK201)(2011/Mar/14 14:33:28)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK201.html?CID=1_1 Mon, 14 Mar 2011 14:33:28 +0800 <![CDATA[HME Heat & Moisture Exchanger (SK200P)(2011/May/26 18:39:53)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK200P.html?CID=1_1 Thu, 26 May 2011 18:39:53 +0800 <![CDATA[HME Heat & Moisture Exchanger (SK201P)(2011/Mar/14 14:50:53)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK201P.html?CID=1_1 Mon, 14 Mar 2011 14:50:53 +0800 <![CDATA[HME Heat & Moisture Exchanger (SK200FT)(2011/Mar/14 14:53:08)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK200FT.html?CID=1_1 Mon, 14 Mar 2011 14:53:08 +0800 <![CDATA[HME Heat & Moisture Exchanger (SK200FT1)(2011/Mar/14 14:55:51)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK200FT1.html?CID=1_1 Mon, 14 Mar 2011 14:55:51 +0800 <![CDATA[HME Heat & Moisture Exchanger (SK201FT)(2011/Mar/14 14:58:55)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK201FT.html?CID=1_1 Mon, 14 Mar 2011 14:58:55 +0800 <![CDATA[HME Heat & Moisture Exchanger (SK201FT1)(2011/Mar/14 15:00:46)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK201FT1.html?CID=1_1 Mon, 14 Mar 2011 15:00:46 +0800 <![CDATA[HME PEDIATRIC HME (SK300P)(2011/May/26 18:44:06)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK300P.html?CID=1_1 Thu, 26 May 2011 18:44:06 +0800 <![CDATA[HME PEDIATRIC HME (SK301P)(2011/May/26 18:45:16)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK301P.html?CID=1_1 Thu, 26 May 2011 18:45:16 +0800 <![CDATA[HME NEW BORN BABY USE HME (SK305)(2011/May/26 18:46:22)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK305.html?CID=1_1 Thu, 26 May 2011 18:46:22 +0800 <![CDATA[HME NEW BORN BABY USE HME W/TUBE (SK305P)(2011/May/26 18:47:53)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK305P.html?CID=1_1 Thu, 26 May 2011 18:47:53 +0800 <![CDATA[HME Heat & Moisture Exchanger (SK205)(2011/May/26 18:48:44)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK205.html?CID=1_1 Thu, 26 May 2011 18:48:44 +0800 <![CDATA[TRACHEO HME Heat & Moisture Exchanger (SK302)(2011/May/26 18:49:28)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK302.html?CID=2_2 Thu, 26 May 2011 18:49:28 +0800 <![CDATA[TRACHEO HME Heat & Moisture Exchanger (SK302P)(2011/May/26 18:50:00)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK302P.html?CID=2_2 Thu, 26 May 2011 18:50:00 +0800 <![CDATA[TRACHEO HME Heat & Moisture Exchanger (SK302CN)(2011/May/26 18:50:33)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK302CN.html?CID=2_2 Thu, 26 May 2011 18:50:33 +0800 <![CDATA[TRACHEO HME Heat & Moisture Exchanger (SK302PP)(2011/Mar/14 15:56:30)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanger-SK302PP.html?CID=2_2 Mon, 14 Mar 2011 15:56:30 +0800 <![CDATA[HMEF HME Filter (FOR USE WITH VENITILATOR/RESPIRATOR) (SK203)(2011/May/26 18:16:06)]]> http://www.saykia-corp.com/06-sk203.html?CID=3_3 Thu, 26 May 2011 18:16:06 +0800 <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK200C)(2011/Mar/15 14:40:25)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanging-Filter-SK200C.html?CID=3_3
  • HMEF  adult                       
  • Paper HME+ electrostatic filtration Filter
  • W/O Sampling Port
  • Recommended T.V. range(ml):250-1000ml
  • Dead space: 32ml
  • Filter efficiency:  BFE>99.99%; VFE>99.99%
  • E.T.O Sterile
  • Resistance(cmH2O):
    • at 30l/min 1.3
    • at 60l/min 3.5
    • at 90l/min 5.2
  • Output Temp @ 2hrs, 10 breaths/minute (ISO 9360).: >29.8mg H2O/l  at T.V 500ml
  • Packing: 50 pcs/inner box, 300 pcs/carton
  • (2011/Mar/15 14:40:25)]]>
    Tue, 15 Mar 2011 14:40:25 +0800
    <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK200CP)(2011/Mar/15 14:43:02)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanging-Filter-SK200CP.html?CID=3_3
  • HMEF adult
  • Ditto data with SK200C
    With CO2 sampling port(2011/Mar/15 14:43:02)]]>
    Tue, 15 Mar 2011 14:43:02 +0800
    <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK200CPE)(2011/Mar/15 14:49:06)]]> http://www.saykia-corp.com/Heat-Moisture-Exchanging-Filter-SK200CPE.html?CID=3_3
  • HMEF   adult
  • Ditto data with SK200CP
    • With CO2 sampling port
    • with Elbow and sampling port by option
    (2011/Mar/15 14:49:06)]]>
    Tue, 15 Mar 2011 14:49:06 +0800
    <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK200ECP)(2011/Mar/15 14:52:43)]]> http://www.saykia-corp.com/Heat-Moisture-Exchanging-Filter-SK200ECP.html?CID=3_3
  • HMEF adult
  • Ditto data with SK200CP
    • With CO2 sampling port
    • with 15/22mm elbow shape socket on machine side
    (2011/Mar/15 14:52:43)]]>
    Tue, 15 Mar 2011 14:52:43 +0800
    <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK201C)(2011/Mar/15 15:03:28)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanging-Filter-SK201C.html?CID=3_3
  • HMEF SK201C
  • Sponger HME+ electrostatic filtration Filter
  • W/O Sampling Port
  • Recommended T.V. range(ml):250-1000ml
  • Dead space: 32ml
  • Filter efficiency:  BFE>99.99%; VFE>99.99%
  • E.T.O Sterile
  • Resistance(cmH2O):
    • at 30l/min 1.05
    • at 60l/min 2.2
    • at 90 l/min 3.5
  • Output Temp @ 2hrs, 10 breaths/minute (ISO 9360).: >29.8mg H2O/l  at T.V 500ml
  • Packing: 50 pcs/inner box, 300 pcs/carton
  • (2011/Mar/15 15:03:28)]]>
    Tue, 15 Mar 2011 15:03:28 +0800
    <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK201CP)(2011/Mar/15 15:06:01)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanging-Filter-SK201CP.html?CID=3_3
  • HMEF                                
  • Sponger HME+ electrostatic filtration Filter
  • W/ Sampling Port
  • Recommended T.V. range(ml):250-1000ml
  • Dead space: 32ml
  • Filter efficiency:  BFE>99.99%; VFE>99.99%
  • E.T.O Sterile
  • Resistance(cmH2O):
  • at 30l/min 1.05
  • at 60l/min 2.2
  • at 90 l/min 3.5
  • Output Temp @ 2hrs, 10 breaths/minute (ISO 9360).: >29.8mg H2O/l  at T.V 500ml
  • Packing: 50 pcs/inner box, 300 pcs/carton
  • (2011/Mar/15 15:06:01)]]>
    Tue, 15 Mar 2011 15:06:01 +0800
    <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK203CP)(2011/Mar/15 15:12:37)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanging-Filter-SK203CP.html?CID=3_3
  • HMEF adult
  • weight: 30g
  • Paper HME+ electrostatic filtration Filter
  • W/ Sampling Port
  • Recommended T.V. range(ml):250-1500ml
  • Dead space: 45ml
  • Filter efficiency:  BFE>99.99%; VFE>99.99%
  • E.T.O Sterile
  • Resistance(cmH2O):
    • at 30l/min 1.05
    • at 60l/min 2.5
    • at 90 l/min 4.8
  • Output Temp @ 2hrs, 10 breaths/minute (ISO 9360).: >30.8mg H2O/l  at T.V 500ml
  • Packing: 50 pcs/inner box, 300 pcs/carton
  • green transparent housing Option
  • (2011/Mar/15 15:12:37)]]>
    Tue, 15 Mar 2011 15:12:37 +0800
    <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK203ECP)(2011/Mar/15 15:15:53)]]> http://www.saykia-corp.com/Heat-Moisture-Exchanging-Filter-SK203ECP.html?CID=3_3
  • HMEF adult
  • weight: 30g
  • Paper HME+ electrostatic filtration Filter
  • W/ Sampling Port
  • Recommended T.V. range(ml):250-1500ml
  • Dead space: 45ml
  • Filter efficiency:  BFE>99.99%; VFE>99.99%
  • E.T.O Sterile
  • Resistance(cmH2O):
    • at 30l/min 1.05
    • at 60l/min 2.5
    • at 90 l/min 4.8
  • Output Temp @ 2hrs, 10 breaths/minute (ISO 9360).: >30.8mg H2O/l  at T.V 500ml
  • Packing: 50 pcs/inner box, 300 pcs/carton
  • (2011/Mar/15 15:15:53)]]>
    Tue, 15 Mar 2011 15:15:53 +0800
    <![CDATA[HMEF Heat & Moisture Exchanging Filter (SK300CP)(2011/Mar/15 15:37:09)]]> http://www.saykia-corp.com/Heat--Moisture-Exchanging-Filter-SK300CP.html?CID=3_3
  • HMEF
  • Pediatric 8-30kgs
  • weight 14g
  • Paper HME+ electrostatic filtration Filter
  • W/ Sampling Port
  • Recommended T.V. range(ml) :70-250ml
  • Dead space: 13ml
  • Filter efficiency:  BFE>99.99%; VFE>99.99%
  • E.T.O Sterile
  • Resistance(cmH2O):
    • at 20l/min1.65  
    • at 30l/min 2.6.
  • Output Moisture & Temp @ 2hrs, 10 breaths/minute (ISO 9360).: >32mg /l & 31.6℃ at T.V 250ml
  • Packing: 100 pcs/inner box,600 pcs/carton
  • (2011/Mar/15 15:37:09)]]>
    Tue, 15 Mar 2011 15:37:09 +0800
    <![CDATA[BACTERIAL Filter Pulmonary Function Filter (SK202L)(2012/Apr/6 15:37:29)]]> http://www.saykia-corp.com/Pulmonary-Function-Filter.html?CID=4_4 To eliminate the cross-contamination.
    Protect your patient and your testing instruments with the Pulmonary Function Filter. provides a high degree of protection for the patient as well as your testing equipment, while its low resistance allows for accurate testing results.Independent laboratory tests have verified that this pulmonary function filter is highly effective. consistently filters out 99.9% of bacteria and 99.9% of viruses.

    According to ATS recommendations for flow resistance in pulmonary function instrumentation, which suggest Resistance should be below 1.5 cm H2O/L/sec at Flow rates less than 12 L/sec1. The easily surpasses that recommendation, having a measured resistance of less than 0.78 cm H2O/L/sec at Flow rates of 12 L/sec.
    1.Am Rev Respir  Dis(1987)136:1285-1298


    • Description:  Disposable Bacterial/Viral Filter, and if included disposable mouthpiece.
    • INTENDED USE:  The “KUNG SHIN” Filter is a disposable bacterial/viral filter designed to prevent biological contaminants from entering pulmonary function testing equipment.
    • DIRECTIONS:
    1. Remove from bag.
    2. Inspect for damage, and dispose immediately if damaged.
    3. Connect securely to pulmonary equipment.
    4. If included, connect mouthpiece to small opening on filter.
    5. After use, dispose of properly.

    { WARNING: The use of this filter and mouthpiece (if included) is limited to a single patient, single session. Not intended for reprocessing. It is not to be used with neonate patients. Do not soak, rinse, wash, gas, or steam sterilize this Product. Patient secretions and wetting with cleaning solutions or liquid detergents may degrade the resistance and effectiveness of this filter.CAUTION: Federal law(USA) restricts this device to sale by or on the order of a physician. }

    (2012/Apr/6 15:37:29)]]>
    Fri, 6 Apr 2012 15:37:29 +0800
    <![CDATA[BACTERIAL Filter Bac./Viral Filter (FOR USE WITH VENITILATOR/RESPIRATOR) (SK202)(2012/Apr/3 14:38:56)]]> http://www.saykia-corp.com/05-sk202.html?CID=4_4 Tue, 3 Apr 2012 14:38:56 +0800 <![CDATA[BACTERIAL Filter B/V Filter (W/O Sampling port low presistance) (SK202N)(2011/Aug/31 10:46:42)]]> http://www.saykia-corp.com/Product-200581715556.html?CID=4_4 Wed, 31 Aug 2011 10:46:42 +0800 <![CDATA[Anesthesia breating circuit & Ventilator Circuit Ventilator Circuit (VT01, VT01W)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/18-peep_valve.html?CID=5_5 VT01W:content 1-6 (with Peep Valve)(2011/Feb/22 09:28:45)]]> Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Anesthesia breating circuit & Ventilator Circuit Anesthesia Breathing Circuit Set, Ditto (A120L Series, A150L Series)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/19-ditto.html?CID=5_5 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Anesthesia breating circuit & Ventilator Circuit Collapsible Circuit (E Series)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-2005105155045.html?CID=5_5 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Anesthesia breating circuit & Ventilator Circuit Disposable Circuit for BiPAP Use (VT05)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-200510516331.html?CID=5_5 Caution: Federal law restricts this device to sale by or on the order of a physician.
    The BiPAP Disposable circuit consists of:
    * Smooth inner lumen tubing
    * Proximal pressure line
    * Disposable Exhalation Port
    * 2 straight Connectors
    * Hook and Loop Fasteners

    Warnings:
    * The exhaust vent on the Exhalation Port is designed to exhaust CO2 from the patient circuit.
    Continuous flow is required for safe operation do not block or otherwise try to seal the exhaust vent on the exhalation port.
    * Before instituting mechanical ventilation, confirm the proper connection of the circuit and verify ventilator operation. Patient, ventilator, and circuit must be monitored on a regular basis per established standards of care.
    * Do not pull or stretch the circuit tubing. This could result in circuit leakage.

    Note: A low- resistance main flow bacteria filter must be placed between the outlet and the circuit tubing.
    (1) Connect a low: resistance, mainflow bacterial filter on the outlet port of the machine. Connect the cuffed end of smooth inner lumen tubing to the outlet port of the filter.
    (2) Connect the other end of the tubing to the patient interface. The vent on the exhalation port should be positioned away from the patient’s face.
    (3) Connecthe proximal pressure line to the port marked "PRESSURE" on the front of the machine unit.

    This circuit is designed for single patient use.
    It is not intended to be cleaned or sterilized.
    The length of time a circuit is used should be determined by the institution’s accepted infection control procedures.

    Made in Taiwan(2011/Feb/22 09:28:45)]]>
    Tue, 22 Feb 2011 09:28:45 +0800
    <![CDATA[Humidification Chamber Disposable - Humidification Chamber (HC-01)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-200673193519.html?CID=6_6 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Humidification Chamber Reusable - Humidification Chamber (HC-02)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-200673110453.html?CID=6_6 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Catheter mount & tube Catheter Mount (CME01W)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/14-catheter_mount-cme01w.html?CID=7_7 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Catheter mount & tube Catheter Mount (CME01)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/15-catheter_mount-cme01.html?CID=7_7 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Catheter mount & tube Catheter Mount (CMF01)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/16-catheter_mount-cmf01.html?CID=7_7 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Catheter mount & tube Catheter Mount (CMF01W)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/17-catheter_mount-cmf01w.html?CID=7_7 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Catheter mount & tube Extendible Extension Tube (FOR USE WITH VENITILATOR/RESPIRATOR) (SK20FT1)(2011/May/26 18:26:33)]]> http://www.saykia-corp.com/10-sk20ft1.html?CID=7_7 Thu, 26 May 2011 18:26:33 +0800 <![CDATA[Catheter mount & tube Flexible Corrugated Tube (FOR USE WITH VENITILATOR/RESPIRATOR) (SK20FT)(2011/May/26 18:25:46)]]> http://www.saykia-corp.com/09-sk20ft.html?CID=7_7 Thu, 26 May 2011 18:25:46 +0800 <![CDATA[Nasal Filter Nasal Filte (HS-04 (M, L))(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-200772235947.html?CID=8_8 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Dental Implanting Items Abutment (54)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-20061121144734.html?CID=9_9 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Dental Implanting Items Analog (55)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-20061121163052.html?CID=9_9 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Dental Implanting Items Healing Abutment (56)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-20061121163310.html?CID=9_9 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[Dental Implanting Items Impression Coping (57)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-20061121163529.html?CID=9_9 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[PE Film PE Embossed Glove Film (KSP-15~30)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-2003722122522.html?CID=10_10 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[PE Film PE Film for Single Package (KSP-18 / KSP-20 / KSP-22)(2011/Feb/22 09:28:44)]]> http://www.saykia-corp.com/Product-200372312939.html?CID=10_10 Tue, 22 Feb 2011 09:28:44 +0800 <![CDATA[PE Film PE Embossed Glove Film (KSP-15~30)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-2003723121217.html?CID=10_10 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[PE Film PE Back Sheet Film (KSP-22 / KSP-24 / KSP-27)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-2003723121356.html?CID=10_10 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[PE Film PE Laminated Non-Wonev or Paper Film (KSPL-33~85)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-2003723121552.html?CID=10_10 Tue, 22 Feb 2011 09:28:45 +0800 <![CDATA[PE Film Waterproof PE Film (KSP-22 / KSP-24)(2011/Feb/22 09:28:45)]]> http://www.saykia-corp.com/Product-2003723121945.html?CID=10_10 Tue, 22 Feb 2011 09:28:45 +0800